initial_step for ac analysis sweeping voltage

From: Geoffrey.Coram <geoffrey.coram_at_.....>
Date: Wed Oct 22 2008 - 06:54:28 PDT
I'm looking at Table 5-1 on the return values of initial_step,
and I think there's still an ambiguity for ac sweeps where
frequency is not the variable being swept.

The header for the AC column says "OP p1 PN" and the
initial_step return values are "1 0 0"

If you do an AC sweep where you sweep voltage, then the
simulator has to compute the OP for each point of the sweep.
So, does initial_step return 1 for each point, because it
is supposed to return 1 for the OP, or 0 because there are
0s under p1 and PN?

-Geoffrey

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
Received on Wed Oct 22 07:16:59 2008