Re: @above in analyses other than tran and dc sweep

From: Ian Wilson <ian.wilson_at_.....>
Date: Wed Nov 18 2009 - 12:53:04 PST
Suppose we run two simulations at values a,b,c for some swept variable, x.

Surely the results for the simulation with x=b should be the same regardless of
whether x had the value a or c in some previous simulation?

I would expect all DC simulations of a circuit with hysteresis to produce the
same result (for the same parameter values), since there is no concept of a previous
state (unless you allow the simulator to start from the operating point calculated in some
other step).

--ian



--
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean. Received on Wed Nov 18 12:53:51 2009