FPGA Configuration:init goes low, addresses keep incrementing (master parallel)


Record #124

Problem Title:
FPGA Configuration:init goes low, addresses keep incrementing (master
parallel)



Problem Description:



Solution 1:




A 4000 family device configuring in master parallel mode may appear to never
finish configuration because the address lines continue changing for long
periods of time without the part ever configuring.

In reality what is probably happening is that the INIT signal has gone low,
indicating that a configuration error has occurred.  This means the checksum
at the end of a data frame did not correlate with the data recieved.
When this happens, the configuration of the device is halted, but the address
lines will continue to toggle!

Causes for the INIT signal to go low: noise, swapped address/data bits
and the most common of all: the design has been compiled for the wrong
parttype (and therefore the frames are different sizes)




End of Record #124