QuickSim: Unable to resolve expression symbol lca_technology, NULL modelwill be inserted
Record #141
Product Family: Software
Product Line: Mentor
Problem Title:
QuickSim: Unable to resolve expression symbol lca_technology, NULL
modelwill be inserted
Problem Description:
Keywords: QuickSim, lca_technology, NULL model
Urgency: Standard
General Description:
In Mentor 8, an error similar to the following may appear when invoking
Quicksim:
// Error: Unable to resolve expression symbol lca_technology (from:
DDMS/EDDM/EDDM General 41)
// Error: Instance: '/BLANK1'
// Trouble accessing MODEL property on primitive instance.
// May be bad property evaluation. NULL model will be inserted.
(from: Analysis/Digital Simulation Utilities/Dsim 16)
// Error: Unable to resolve expression symbol lca_technology (from:
DDMS/EDDM/EDDM General 41)
// Error: Instance: '/BLANK2'
// Trouble accessing MODEL property on primitive instance.
// May be bad property evaluation. NULL model will be inserted.
(from: Analysis/Digital Simulation Utilities/Dsim 16)
// Error: Unable to resolve expression symbol lca_technology (from:
DDMS/EDDM/EDDM General 41)
// Error: Instance: '/BLANK3/UNKNOWN1'
// Trouble accessing MODEL property on primitive instance.
// May be bad property evaluation. NULL model will be inserted.
(from: Analysis/Digital Simulation Utilities/Dsim 16)
Solution 1:
For XACT 5.x users:
This is caused by a non-existent or incorrectly written simulation
viewpoint for the design. The solution is to run PLD_DVE_Sim on the
design, specifying the correct part family, from either PLD Design Manager
or the command line. An XC4000 design, for example, would use:
pld_dve_sim blanking_design xc4000
If a default viewpoint already exists, you will need to FIRST delete that
viewpoint before you can run PLD_DVE_Sim. See (Xilinx Solution 766).
Note: If Timsim8 -o was used to create the simulation model, be sure to run
Timsim8 instead of PLD_DVE_Sim. This is because Timsim8 -o links timing
information into the viewpoint after it runs PLD_DVE_Sim.
Solution 2:
For XACT M1 users:
This is caused by a non-existent or incorrectly written simulation
viewpoint for the design. The solution is to run PLD_DVE -S on the
design, specifying the correct part family, from either PLD Design Manager
or the command line. An XC4000E design, for example, would use:
pld_dve -s blanking_design xc4000e default
Since PLD_DVE in M1 annotates pre-existing viewpoints, there is no need
to first delete a pre-existing viewpoint.
End of Record #141