93 DATA BOOK: Error in boundary scan order for 4004a on p. 2-77


Record #165

Product Family:  Hardware

Product Line:  4000A

Problem Title:
93 DATA BOOK: Error in boundary scan order for 4004a on p. 2-77


Problem Description:
In the middle of the 2nd column on page 2-77 in the 1993 data
book(first edition), four pins are given boundary scan order
numbers of 169, 172, 211, and 214.
These numbers are incorrect.

These pins should not have numbers assigned to them.


Solution 1:

Updated pinout is given on page 2-83 of the 94 DATA BOOK (starting with the firs
t edition).

The latest copy of the Xilinx Programmable Data Book can be found
on the Xilinx Web site:

  www.xilinx.com -> DataBook




End of Record #165