Answers Database
Powerview: values not displayed on schematic during simulation
Record #218
Product Family: Software
Product Line: ViewLogic
Problem Title:
Powerview: values not displayed on schematic during simulation
Problem Description:
Simulation values are not being back-annotated and displayed on the schematic
during simulation. One likely cause of this is copying a vsm file to a
different name using the UNIX cp command, then simulating from it. In order
for the connection between a schematic and a simuation to occur, the vsm file
must have the same name as the schematic. Often the vsm file produced by the
back-annotation process does not have the same name.
Solution 1:
There is a command in ViewSim that changes the name of the schematic that the
annotation should be sent to. Use this command to annotate values to your
top level design:
SCHEMNAM <design>
where <design> is the name of your top-level schematic.
Solution 2:
End of Record #218