Answers Database
94 DATA BOOK: 4005H boundary scan pinout incomplete page 2-101
Record #234
Product Family: Hardware
Product Line: 4000H
Problem Title:
94 DATA BOOK: 4005H boundary scan pinout incomplete page 2-101
Problem Description:
The 4005H boundary scan pinout in the 1994 databook is incomplete.
It is missing the following entries:
MQ240 Bound. Scan#
99 385
102 391
107 403
136 475
162 535
167 547
205 56
The pinout is identical to the boundary scan pin numbering for the
4013 in the pq240 package.
Solution 1:
These corrections were made in the 1994 data book second edition
End of Record #234