Answers Database
SDT2XNF, INF2XNF ERROR 1, internal program error, code 0, return code 3
Record #294
Product Family: Software
Product Line: OrCad
Problem Title:
SDT2XNF, INF2XNF ERROR 1, internal program error, code 0, return code 3
Problem Description:
Customers using XEPLD v5.0 tools with the old libraries could receive the
following error from sdt2xnf:
INF2XNF: Fatal Error:
----------------------------------------------
DS35-SDT-ERROR-001:
An internal program error occurred, code '0'.
----------------------------------------------
...
Return code from 'inf2xnf <parameters>' = 3
Solution 1:
This is due to an error in the library files for the PLOUT8A component.
Use individual PLOUTT components instead of PLOUT8A.
End of Record #294