Answers Database
Differences between the 7318/7336 and 7354/7372/73108/73144
Record #472
Product Family: Hardware
Product Line: 7300
Problem Title:
Differences between the 7318/7336 and 7354/7372/73108/73144
Problem Description:
Engineers designing for the XC7300 family of EPLDs should be aware of the
following architechtural differences between members of this family:
XC7318/36/144 vs. XC7354/72/108 Fast Function Blocks
============================================================
XC7318/36/144 XC7354/72/108
------------------------------------------------------------
Output polarity control Fixed output polarity
Direct support for D- or T-flip-flop D-flip-flop only
Flip-flop asynchronous set or reset Flip-flop asynchronous set only
XC7318/36 vs. XC7354/72/108/144 I/O Blocks
============================================================
XC7318/36 XC7354/72/108/144
------------------------------------------------------------
Direct input only Direct, latched, or registered input
No input polarity control Input polarity control
Also note that, because the XC7318 and XC7336 contain only Fast Function
Blocks, all flip-flop clock signals must be on the FCLK nets, and all
output enable signals must be on the global FOE nets.
Solution 1:
End of Record #472