Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


7336 or 7318 functions incorrectly after being programmed by Data I/O programmer


Record #666

Product Family:  Hardware

Product Line:  7300

Problem Title:
7336 or 7318 functions incorrectly after being programmed by Data I/O
programmer



Problem Description:
A 7336 or 7318 chip appears to partially function, and/or not function after
programming.


Solution 1:

Erratic 7336 and 7318 behavior can be caused by using older programming
algorithms for the 7336/7318 with Data I/O programmers.

If you program a 7336 and/or 7318 with Data I/O programmers, make sure
that the programming software is the version listed below or later.

	Programmer	  Software Version
	 2900				3.6
	 3900				2.6
	 Autosite			      2.6
	 Unisite			4.8



End of Record #666