Answers Database
Fncsim8/XBLXGS fails under Mentor B.x with "call to undefined procedure"
Record #786
Product Family: Software
Product Line: Mentor
Problem Title:
Fncsim8/XBLXGS fails under Mentor B.x with "call to undefined procedure"
Problem Description:
While running XBLXGS (under Fncsim8) on a system with Mentor Graphics B.x
installed, you may get the following error:
ld.so: call to undefined procedure
___sti__Isrc_eri_render_C_eri__render_debug_ from 0x302778
This is caused by an incompatibility between XACT 5.2.1 (written for Mentor
A.x) and Mentor B.x.
Solution 1:
A patch is available on the Xilinx FTP site. For more information, see
Solution 997, "Using XACT 5.2.1 with Mentor Graphics' B.1/B.2 release"
End of Record #786