XDE/EDIT LCA 5.2: INTERNAL PROGRAM ERROR (Please contact support personnel): bprog: 19,6: 10: not a pip


Record #794

Product Family:  Software

Product Line:  FPGA Core

Problem Title:
XDE/EDIT LCA 5.2: INTERNAL PROGRAM ERROR (Please contact support
personnel): bprog: 19,6: 10: not a pip



Problem Description:
Problem:
When editing the CLB in LCA file,  the following error could occur:

      15:   35	 15: yq_qy: not a pip
      16:   11	  7: h2_f: not a pip
      17:   11	  9: h_h1: not a pip
      18:   11	 13: h_g: not a pip
      19:   27	  3: ffx_k: not a pip
      20:   27	 12: ffy_k: not a pip
      21:   26	 17: ffy_set: not a pip
      22:   26	 11: ffy_reset: not a pip
      23:   26	  8: ffx_set: not a pip
      24:   26	  1: ffx_reset: not a pip
      25:   28	  5: xqec_ec: not a pip
      26:   28	 14: yqec_ec: not a pip
      27:    7	  8: f_din_din: not a pip
      28:    3	  9: f_we: not a pip
      29:    7	 18: g_din_din: not a pip
      30:    7	 19: g_din_h1: not a pip
      31:    3	 17: g_we: not a pip
     INTERNAL PROGRAM ERROR (Please contact support personnel):
     bprog: 19,6: 10: not a pip.
     INTERNAL PROGRAM ERROR (Please contact support personnel):
     bprog: 35,6: 58: not a pip.
     INTERNAL PROGRAM ERROR (Please contact support personnel):
     bprog: 27,3: 18: not a pip.
     Press any key to continue.

Cause:
The problem here is that a certain data file which defines the internals
of the 4000 CLB is not installed properly.  The file is f4000fg.xcb,
and it should be in the \xact\data directory.  The correct file is:
 F4000FG.XCB	5,477 bytes 10/23/95 2: 24: 10 PM

If you are upgrading your software from 5.2.0 beta to 5.2.0, if you are installi
ng the software in the same directory, and if the data file f400fg.xcb is not in
stalled, then the software trys  to use the data file of Beta version software w
ith the 5.2 Production Release software.  This could result in Internal Program
Error when editing the CLB in his LCA file.





Solution 1:

alternate sol'n:

copy the entire xact/data directory off the CD to your xact/data directory.



Solution 2:

Copy the f400fg.xcb file from the \XACT\DATA directory on the install CDROM
into the XACT\DATA directory on your disk.