XABEL-CPLD: Switching between 9500 and 7300


Record #859

Product Family:  Software

Product Line:  Data I/O

Problem Title:
XABEL-CPLD: Switching between 9500 and 7300


Problem Description:
There are currently two versions of the XABEL-CPLD software available: the
production release, and the XC9500 pre-release version.

If both versions are installed on the same machine, only the most recently
installed version will run.  Each installation of XABEL-CPLD changes the
Windows registration database.


Solution 1:

There is a subdirectory called INSTALL in both the XABEL-CPLD directory and
the 9500 SW directory.	Inside this directory is a registration script called
XABEL.REG which can be run using File Manager.

Run the XABEL.REG script for the version of XABEL-CPLD you wish to run.
This will update the Windows registration database.

A Program Item can also be created from the script to quickly execute it.



End of Record #859