Foundation: Library access errors


Problem Description:
Library access errors occur when opening a project.


Solution 1:

One possible cause is insufficient conventional memory.

460kB of free conventional memory is recommended.  This
number reflects the amount of free conventional memory
available while Windows is running.



Solution 2:

Libraries which are shared by multiple users over a network
must have the Read Only attribute set, or the entire library
directory must be protected with the Read Only attribute.

If the Read Only attribute is not set, one user will be able
to access the libraries.  Any other users who attempt to use
the libraries at the same time will see the library access
error.



End of Record #900