Answers Database
HW-130: 7372 is non-functional if security bit is programmed
Record #1004
Product Family: Hardware
Product Line: Programmers
Problem Title:
HW-130: 7372 is non-functional if security bit is programmed
Problem Description:
There was a known problem in revision 2.03 of the HW-130 software (v1.06
of the 7372 algorithm) in which programmed 7372 devices did not work if the
security bit was programmed. This was fixed in version 2.04 of hw130, which
was made available on the Xilinx BBS at the end of March 1996.
Solution 1:
Download the latest version, v2.04, of the hw130 program from the BBS. This
archive includes the fixed 7372 algorithm, v1.07.
End of Record #1004
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |