Design Manager 6.0.x: Unhandled exception, xact raw binary interface error


Record #1041

Product Family:  Software

Product Line:  FPGA Core

Problem Title:
Design Manager 6.0.x: Unhandled exception, xact raw binary interface
error



Problem Description:
When starting up Design Mangager, get system error
Unhandled exception
Xact Raw binary interface error


Solution 1:

Delete (make backup) the DSGNMGR.INI file from the WINDOWS directory
(or the directory point at by XACTUSER).  Design Manager will create a
new DSGNMGR.INI file.  May get one more errors when opening up
Design Manager again for the first time.  You should be able to get by
this error and create a new project.  The Design Manager should work
again after this.