Answers Database
COMPOSER: Incorrect SCHNM property on ILD1 causes XNF2CDS "no corresponding entry" error
Record #1093
Product Family: Software
Product Line: Cadence
Problem Title:
COMPOSER: Incorrect SCHNM property on ILD1 causes XNF2CDS "no
corresponding entry" error
Problem Description:
The SCHNM property on the ILD1 symbol in the XC4000 Composer
library is incorrectly designated as "ILD_1" instead of "ILD1".
This causes the following error in XNF2CDS:
ERROR : The following symbol(s) were found in the design, but do
not have corresponding entries in the PIN file :
Symbol I418 (type INLAT)
Symbol I420 (type INLAT)
Symbol I421 (type INLAT)
Solution 1:
Change the SCHNM property on the ILD1 symbol from "ILD_1"
to "ILD1".
End of Record #1093
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |