Answers Database
"Can't open display" error when invoking install and other programs withgraphical interfaces
Record #1163
Product Family: Software
Product Line: Merged Core
Problem Title:
"Can't open display" error when invoking install and other programs
withgraphical interfaces
Problem Description:
The "Can't open display" error means that an application is unable to
write to the user's workstation display. This usually happens when you
are running graphical software while remotely connected to a workstation
from your own machine.
Solution 1:
There are two ways this can happen.
1) Often the customer has not started OpenWindows (or any
other X server) before running the install.
The solution is to start Openwindows first. If the
user REALLY doesn't want to run X, or doesn't have
a graphical monitor for the system with the CD, there's
a second, non-graphical install script,
/cdrom/cdi.csh,
which can install the XACT software; however, it has less functionality
than the graphical install.
2) Even if openwin or X is running, the display is
protected by default so that no one else can connect.
If the customer does "su" to become root, and runs the
install, the X server won't let root connect to the
user's display.
The solution here is to have the user type
"xhost +"
as himself
from a command tool in which he is logged on to his LOCAL machine.
This will allow root as well as other users to write to the user's
display.
If you are invoking the software from the remote machine, you must also
first set the DISPLAY environment variable to "hostname:0" in the
command tool connected to the REMOTE machine. In this case, "hostname"
is the hostname of your LOCAL machine:
setenv DISPLAY `hostname`:0
This will allow root as well as other users to write to the user's
display.
3) On Solaris systems, an additional step is required as a workaround
This problem happens because the XACT programs are statically
linked in an environment which uses NIS. They consequently
can't find network information in an environment which uses DNS.
This affects the X programs, and also the license manager.
Solution 2:
Although running the Xilinx software on a remote PC X-Server
utility is not supported by Xilinx, and has never been tested.
It has been found that by using the complete IP address in the
display variable sometimes will solve the Can't Open Display problem.
End of Record #1163