Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


procapture dos error #75 occurred: access denied...


Record #1182

Product Family:  Software

Product Line:  ViewLogic

Problem Title:
procapture   dos error #75 occurred:  access denied...


Problem Description:
When trying to open procapture (from proflow) the following error occurs:

dos error #75 occurred:  access denied, opening c:\xact\data\partlist.xct for xi
linx device data load:Fopens


Solution 1:

This error could be caused by overwriting partlist.xct from the partlist.xct
on the xact5.2.1/6.0.1 CD.  (if, for example, you needed the new 4025e
partlist).  It is possible that the file could be copied with the R
(read-only) attribute set.  Type the following command to see if this is
the case:

attrib c:\xact\data\partlist.xct

The only attribute that should be set is the 'A' attribute.  If the 'R' attribut
e is set type the following to remove it:

attrib -r c:\xact\data\partlist.xct

This can also be done within the File Manager in Windows.  Select the file
and hit ALT-ENTER.  You will see the Read-Only box checked (or not).  Make
sure it is not checked.



End of Record #1182

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved