Foundation 6.x : Saving simulation probes and I/O signals


Record #1317

Product Family:  Software

Product Line:  Aldec

Problem Title:
Foundation 6.x : Saving simulation probes and I/O signals


Problem Description:
Keywords: Foundation simulation probe save
Urgency: Standard

General Description:

This is the procedure to save the probes placed on the
schematic, signals added to the Waveform Viewer in the
simulator, and stimulators on these signals so that they may
be brought back for future simulations.


Solution 1:

1.  Place all desired simulation probes on the schematic
    using the SC Probes toolbar menu or select the signals
    you wish to view from the Signal --> Add Signals dialog
    box in the Foundation Logic Simulator.  Set up any
    stimulators that will be used every time this design is
    simulated, such as clocks, constants (0 or 1), or
    formulas.

2.  In the simulator, select File --> Save Test Vectors.
    Enter a name to save simulation data and click OK.

3.  To load the signal list and stimulators, select File -->
    Load Test Vectors.	Select the appropriate filename and
    click OK.