Foundation: Can you put LOCs on IPAD4/8/16 or OPAD4/8/16?


Record #1396

Product Family:  Software

Product Line:  Aldec

Problem Title:
Foundation: Can you put LOCs on IPAD4/8/16 or OPAD4/8/16?


Problem Description:
You cannot put LOC attributes on the bussed I/O pads that are
contained in the Xilinx libraries (IPAD4/8/16, OPAD4/8/16,
and IOPAD4/8/16).


Solution 1:

The workaround is to copy the Xilinx library component to a
user library so you can edit the schematic underneath, adding
the LOC attributes.

You may need to make multiple copies of the component.	For
example, if you want to place 2 IPAD4 components, each one
having a different set of LOC attributes, you would make 2
copies of the IPAD4 and put different LOCs inside each one.

Refer to (Xilinx Solution 1657) for instructions on copying
a Xilinx library component.

After copying a component, edit the schematic under the
symbol to add the LOC attributes:

1) Open the Schematic Editor.
2) Select File -> Open and select the copied macro from the
   list of macros.
3) Add the LOC attribute to the individual pad symbols.