Answers Database
XChecker: "Done did not go high" for 5200 download.
Record #1402
Product Family: Software
Product Line: FPGA Core
Problem Title:
XChecker: "Done did not go high" for 5200 download.
Problem Description:
Keywords: done, high, xchecker
Urgency: Standard
General Description:
The XChecker software can be used as a stand-alone tool
(ie. it does not need to be used within the XACT environment).
Though in order to use the XChecker program to download a 5200
device the partlist.xct file needs to be available. If the
partlist.xct file is not available the XChecker program will
report "Done did not go high".
Solution 1:
In order to fix this problem do one of the following:
1) Set the XACT variable to the XACT directory, there should
be a data directory within the XACT directory that contains the
partlist.xct file.
2) Copy the XACT\data\partlist.xct file to the current working
directory (the directory you will be running xchecker from).
A quick check to verify that the partlist.xct file is available
is to type device at the XCHECKER prompt, if it returns a list
of available devices then everything is ok.
End of Record #1402