Answers Database
Timing Analyzer 6.0.1: Cannot print .XRP from Timing Analyzer when running Windows 95
Record #1466
Product Family: Software
Product Line: FPGA Core
Problem Title:
Timing Analyzer 6.0.1: Cannot print .XRP from Timing Analyzer when
running Windows 95
Problem Description:
Keywords: xrp, print
Urgency: Standard
General Description:
Attempting to print .XRP file from Timing Analyzer 6.0.1 yields
a Windows 95 "System Error" dialog box with the following error
message:
FATAL ERROR: MSG 0x0073c35f [CAT 7/3 STD 50015]
Category: Underlying system generated error [Toolkit error]
Function: xvt_print_create xvt_dlg_create_res xvt_app_create
File: wprnt.c line: 704
Solution 1:
Since XACTstep 6.0.1 was developed for Windows 3.11, there are
some incompatibilities with Windows 95. This is one of them,
and there currently is no fix for this.
If you can save your report in Timing Analyzer, then please
refer to Resolution 2 of this solution record.
Solution 2:
You can print the timing report by saving the timing report
(Xilinx Solution 1221), opening the saved document in another
text editor (Notepad, Word, etc), and printing the report from
within the respective text editor. The saved report will be a
standard text file.
End of Record #1466