FPGA Configuration: Xchecker - stand alone "ERROR 264: DONE signal did not go high"


Record #1469

Product Family:  Software

Product Line:  FPGA Core

Problem Title:
FPGA Configuration: Xchecker - stand alone "ERROR 264: DONE signal did
not go high"



Problem Description:
Xchecker gives Error 264 when downloading a .bit file but not any other file for
mat (.tek, .mcs, ...).



Solution 1:

If Xchecker cannot find the partlist.xct file in the current directory or in the
 \xact\data directory then xchecker will report Error 264.

Put a copy of the partlist.xct in the same directory as xchecker.exe.