XC9500: Power consumption/dissipation information
Record #1480
Product Family: Hardware
Product Line: 9500
Problem Title:
XC9500: Power consumption/dissipation information
Problem Description:
Operating current for an XC9500 design can be approximated
for specific operating conditions using the following
equation :
Icc(mA)=MChp (1.7) + MClp (0.9) + MC (0.006 mA/MHz) f
Where :
MChp = Macrocells in high-performance mode
MClp = Macrocells in low-power mode
MC = Total number of macrocells used
f = clock frequency
Power dissipation can be reduced in the XC9500 by configuring
macrocells to standard or low-power modes of operation.
Unused macrocells are turned off to minimize power dissipation.
Typical Icc vs. Frequency graphs are available for the various
XC9500 devices in Chapter 3 of the 1996 Xilinx Programmable Logic
Data Book.
Please refer to this chapter for more information on low-power
mode as well as additional information on the specific XC9500
device you are targeting.
Solution 1:
Solution 2:
To obtain power, multiply Vccint by Icc
for the sake of overall power, the i/o voltages are
negligible with respect to the power calculation.
End of Record #1480