Answers Database
PROsim: Simulation with OSC4.1: could not find WIR file xc4000:osc4.1
Record #1550
Product Family: Software
Product Line: ViewLogic
Problem Title:
PROsim: Simulation with OSC4.1: could not find WIR file xc4000:osc4.1
Problem Description:
When running timing simulation with PROseries tools, VSM will give following err
or message on XNFBA.1
Error - could not find WIR file xc4000:osc4.1
Solution 1:
Check the box that says:
"Design contains XBLOX, RAM, ROM, or XABEL Modules", in the functional
simulation even if this is not the case.
End of Record #1550