Answers Database
"error #83 buffer too small" is given when starting PROcapture
Record #1559
Product Family: Software
Product Line: ViewLogic
Problem Title:
"error #83 buffer too small" is given when starting PROcapture
Problem Description:
"error #83 buffer too small" is given when starting PROcapture
This error maybe caused because there is more than one project.lst file
present. This can occur if there is more than one Viewlogic package installed.
For example: Workview Office and Pro Series.
Solution 1:
Modify the autoexec.bat so it refers to exactly one set of software.
Do not mix and match with different versions of Viewlogic Software. If you
have Workview Office and Pro Series within the same operating system, you
must create a batch file for each setup.
End of Record #1559