Answers Database
XACT-CPLD: rg37:[Warning] Programming output for device type 95144160 isnot supported
Record #1594
Product Family: Hardware
Product Line: 9500
Problem Title:
XACT-CPLD: rg37:[Warning] Programming output for device type 95144160
isnot supported
Problem Description:
Using XACT-CPLD, the Design Manager may fail in the programming
file generation phase with the following error:
Programming File Generator Version XACT-CPLD-V6.0.2a
(c) Copyright 1989-1995 Xilinx Inc. All rights reserved.
Design Name: calc9k
rg37:[Warning] Programming output for device type 95144160
is not supported in this release.
You will notice that the JEDEC file produced will be empty(0 bytes).
Solution 1:
This message indicates that the data files necessary to create
the JEDEC file are not yet available, since the device being
targetted, XC95144, is not yet available. When it is ready,
the necessary data files and software patches will be made
available via FTP/BBS.
Before this time, you have the option of targetting a 95144
to evaluate the fitting and timing characteristics of the
design, so that when the part is available, the device can be
programmed with the design. Also, you can fit the design to a
73144 with the same pinout, which is currently available, and migrate to the 951
44 at a later time.
End of Record #1594