Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


XNF2WIR Error 13: Unsupported XNF netlist version '6'.


Record #1710

Product Family:  Software

Product Line:  ViewLogic

Problem Title:
XNF2WIR Error 13: Unsupported XNF netlist version '6'.


Problem Description:
When running XSimmake functional flow, if the versions of the Core tools
and the Viewlogic Interface don't match, then xnf2wir can give the
following error:
ERROR 13: Unsupported XNF netlist version '6'.
Supported versions are: 1,2,4,5

This can happen if the XACT tools (DS502) have been updated to version 5.2.1,
but the Viewlogic Interface tools (DS391) are older; versions 5.1 or 5.0.


Solution 1:

Check the xsimmake.out to find out which versions of all the programs are being
executed.

Make sure that environment is set so that it is running version 5.2.1 for both D
S391(Viewlogic interface), and DS502(FPGA core tools).

Update the Viewlogic Interface tools to 5.2.1, if it is 5.0 or 5.1.



End of Record #1710

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents