Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


CONCEPT2XIL Error #169: Port modes are not the same. The entity declaration needs to be updated


Record #1722

Product Family:  Software

Product Line:  Cadence

Problem Title:
CONCEPT2XIL Error #169: Port modes are not the same. The entity
declaration needs to be updated



Problem Description:
Keywords: port mode entity declaration concept2xil

Urgency: standard

General Description:

<OUTPUT> "Error #169: Port modes are not the same. The entity
declaration needs to be updated"
</OUTPUT>

You may see an error like this if the ports in the ENTITY
declaration created by HDL Direct for a body drawing do not
match the ports on the SYMBOL BODY for the same design block.

This error is seen in the 97A Cadence release.


Solution 1:

Bring up the symbol body in question in Concept and rewrite
(re-save) it.  Doing this will ensure that the entity
corresponding to the symbol body will be regenerated based on
the current version of the symbol drawing:

   edit foo.body
   write



End of Record #1722

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents