Answers Database
CONCEPT2XIL/HDLCONFIG: Warning: No acceptable view exists for cell AND2 in library <path_to_library>
Record #1727
Product Family: Software
Product Line: Cadence
Problem Title:
CONCEPT2XIL/HDLCONFIG: Warning: No acceptable view exists for cell AND2
in library <path_to_library>
Problem Description:
Keywords: acceptable view hdlconfig
Urgency: standard
General Description:
CONCEPT2XIL HDLCONFIG: Warning: No acceptable view exists for
cell AND2 in library <path_to_library>
This warning is seen in the 97A Cadence release.
Solution 1:
This warning is issued by the HDLCONFIG program and indicates
that the LOGIC and PICSYNTH view is missing for the specified
library component. The warning is usually only issued on
primitives, for which the LOGIC and PICSYNTH views are
unnecessary.
In general, the warnings can be safely ignored, despite the
reference to there not being any "acceptable" views.
End of Record #1727