Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


ViewDraw Symbols May Not Be Updated Properly After Entering a Change LogiBLOX Command


Record #1751

Problem Title:
ViewDraw Symbols May Not Be Updated Properly After Entering a Change
LogiBLOX Command



Problem Description:
Platform(s): All
Architecture(s): All
Design Step(s): Design Entry with LogiBLOX
Reference Number: 9600
If you perform a Change LogiBLOX command in ViewDraw without
choosing a new module name, the updated symbol may not be
displayed properly in the ViewDraw schematic.


Solution 1:

If the size of the new symbol is different than that of the old one - typically
the case when you change the basic type of a module - the selection outline will
 not be aligned with the graphical representation of the symbol. To correct this
, save the schematic and choose the Read command from the ViewDraw File menu to
read it back in.