dsgnmgr M1.1.1a: "Cannot find tool definition file..."
Record #1944
Problem Title:
dsgnmgr M1.1.1a: "Cannot find tool definition file..."
Problem Description:
Invoking the DSGNMGR causes the following Error message to be displayed:
"Cannot find tool definition file"
This is caused by installing the M1.1.1a Software in a directory path that
contains Upper-case letters. For example: /usr/xilinx/M1.1.1a as the
installation path will cause this error to occur.
Solution 1:
Move the M1.1.1a 4kEX Pre-release to a directory path that does not contain
any upper-case letters in the directory names:
(For example: /usr/xilinx/m1.1.1a/).
Solution 2:
If the installation path cannot be changed, then a fake installation path, that
contains only lower case letters, can be linked to the actual, which may contain
upper case letters. For example:
If the software is installed in /usr/products/XILINX for example,
the work around would be to create a link to this directory using
lower case:
ln -s /usr/products/XILINX /usr/products/xilinx
setenv $XILINX /usr/products/xilinx
End of Record #1944