Answers Database
XEPLD 6.0: hi604: [Warning] Unexpected TIMESPEC string ignored
Record #2084
Product Family: Software
Product Line: EPLD Core
Problem Title:
XEPLD 6.0: hi604: [Warning] Unexpected TIMESPEC string ignored
Problem Description:
Keywords: xemake6, hi604, constraints, xact-performance
Urgency: Standard
General Description:
Upon invoking "xepld" on a 9500 part, the following may be encountered if you ha
ve TIMESPECS in the design or in a constraints file:
hi604:[Warning]Unexpected TIMESPEC string FROM:PADS(PTOHP):TO:FFS=8.0, Ignored.
Note that XC7000 devices support FROM:TO syntax and do not
support the old-style P2P, C2S timing specifications.
The TIMESPEC is valid, and the signal "PTOHP" does indeed exist in the .xnf file
.
Solution 1:
The problem is that XEPLD calls a subprogram "xemake6", and this program has a b
ug. It will not accept any TIMESPEC string that references a signal with the str
ing "TO" in it. Therefore, the signal "PTOHP" will need to be renamed to somethi
ng else, such as "P2HP".
End of Record #2084