Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


9500 ESD information


Record #2126

Product Family:  Hardware

Product Line:  9500

Problem Title:
9500 ESD information


Problem Description:
Keywords: 9500, esd, 95108, reliability

Urgency: standard

General Description:

Electrostatic Data for XC9500 Family is not available in the
September 1996 Data Book.


Solution 1:

Device	      Human Body Model		Charge Device Model
	      Worst Case ESD		Worst Case ESD
	      Mil-Std-883D
	      Method 3015
-------------------------------------------------------------

XC9536	      >3000V			(+/-)2000V*
XC9572	      (+/-)5000V		(+/-)2000V*
XC95108       (+/-)2000V		(+/-)2000V*
XC95216       (+/-)2000V		(+/-)2000V*

*Measured on XC95108

The 9500 ESD information will be included in the next databook.
The information is currently published in the Jan. 1, 1997
"The Reliability Data Program".