Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


HW-130: programmer displays "HW-133-PG84" when TQ100 adapter is used.


Record #2129

Product Family:  Hardware

Product Line:  Programmers

Problem Title:
HW-130: programmer displays "HW-133-PG84" when TQ100 adapter is used.


Problem Description:
KEYWORDS:
HW-130, programmer, TQ100, adapter, PG84, HW-133 hw130

URGENCY:
standard

GENERAL DESCRIPTION:
When using HW-130 prgrammer with TQ100 adapter in place, the programmer may inco
rrectly identify the adapter as
"HW-133-PG84".



Solution 1:

This is a bug with v4.0 of the HW-130 software.  It will
be fixed in v4.1.

There should NOT be any problem continuing to use TQ100 adapter.  The programmin
g of the device is not be affected.



End of Record #2129

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents