Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


9500: xchecker rcab error 4059


Record #2133

Product Family:  Software

Product Line:  EPLD Core

Problem Title:
9500: xchecker rcab error 4059


Problem Description:
Keywords: 9500, 4059, xchecker, cab

Urgency: standard

General Description:

Trying to download a 9500 devices using the Xchecker cable may
lead to an 'Error 4059' or 'rcab error' message from Eztag.



Solution 1:

There is a patch, now available to fix the rcab problem.

The fix requires only that a new FPGA design file be used
when the xchecker is being run for JTAG-based download.  This
means no cable modification is required at all - only one file
is updated (xckjtag.sys)

It has been decided to release a new full version of EZTag
(V6.0.6) that includes the new FPGA design file and, it is
available on the ftp site:

ftp://ftp.xilinx.com/pub/swhelp/cpld/eztag_pc.zip   - for PCs
				     eztag_hp.tar.Z - For HP-UX
				     eztag_sn.tar.Z - For SunOS





End of Record #2133