Answers Database
9500: xchecker rcab error 4059
Record #2133
Product Family: Software
Product Line: EPLD Core
Problem Title:
9500: xchecker rcab error 4059
Problem Description:
Keywords: 9500, 4059, xchecker, cab
Urgency: standard
General Description:
Trying to download a 9500 devices using the Xchecker cable may
lead to an 'Error 4059' or 'rcab error' message from Eztag.
Solution 1:
There is a patch, now available to fix the rcab problem.
The fix requires only that a new FPGA design file be used
when the xchecker is being run for JTAG-based download. This
means no cable modification is required at all - only one file
is updated (xckjtag.sys)
It has been decided to release a new full version of EZTag
(V6.0.6) that includes the new FPGA design file and, it is
available on the ftp site:
ftp://ftp.xilinx.com/pub/swhelp/cpld/eztag_pc.zip - for PCs
eztag_hp.tar.Z - For HP-UX
eztag_sn.tar.Z - For SunOS
End of Record #2133