Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


map m1.2-ws: FATAL_ERROR:baste:bastetspec.c:2317:1.62 - NET OFFSET...


Record #2191

Product Family:  Software

Product Line:  Merged Core

Problem Title:
map m1.2-ws: FATAL_ERROR:baste:bastetspec.c:2317:1.62 - NET OFFSET...


Problem Description:
Keywords: NET, OFFSET, IOBCOMP

Urgency: Standard

General Description:

FATAL_ERROR:baste:bastetspec.c:2317:1.62 - NET OFFSET 'DATA2 IN :
10000.000000 pS : AFTER : CLK2' has no data IOBCOMP. Process will
terminate.  Please call Xilinx support.


Solution 1:

This error message is only caused when an IOB signal referenced in a
NET OFFSET constraint such as:

NET DATA2 OFFSET = IN 10 AFTER CLK2;

is trimmed or removed from the design.	To workaround this, comment
out or remove the OFFSET constraint.  To determine why the signal is
being deleted check the Logic Trimming section of the mapper report:
<design>.mrp.



End of Record #2191