Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


5200: Readback with xchecker on 5202 devices


Record #2196

Product Family:  Hardware

Product Line:  5200

Problem Title:
5200: Readback with xchecker on 5202 devices


Problem Description:
Keywords: 5200, 5202, readback, XACTstep 5.2.1/6.0.1, xchecker

Urgency: Hot

Description

XACTstep 5.2.1/6.0.1 can not perform readback with xchecker on
5202 devices.


Solution 1:

Current XACTstep 5.2.1/6.0.1 does not support readback with xchecker for 5202.
However, readback is supported in the rest
of 5200 family. makebits program needs to run with following options:


Makebits -l -f readcapture:enable <design>


Users should understand this is not an architectural problem
but a software limitation.



End of Record #2196

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents