Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


Xsimmake reports no license for schematic in Pro Series


Record #2203

Product Family:  Software

Product Line:  FPGA Core

Problem Title:
Xsimmake reports no license for schematic in Pro Series


Problem Description:
PROseries simulation fails when xsimmake.out reports no license for schematic.


Solution 1:

If the system has both PROseries and Workview Office installed, only one of
these Viewlogic tools can be referenced in the AUTOEXEC.BAT file.  Both of
these tools require the PATH and WDIR, and you cannot specify these variables
to both tools at one time.

Our recommendation is to only have one of these toolsets installed locally,
but if both are necessary, create batch files to set up unique environments
for the two tools.



End of Record #2203