Answers Database
Template Manager M1: Error "For the Report limit value, please enter integer.."
Record #2316
Product Family: Software
Product Line: FPGA Core
Problem Title:
Template Manager M1: Error "For the Report limit value, please enter
integer.."
Problem Description:
Keywords: Template, Timing, Report, Limit, path, value
Urgency: Standard
General Description:
When editing the Timing Constraint Paths limit, to limit the Report to a
certain number, and entering in a user number clicking "OK" gives the
following error:
! For the Report Limit Value, please enter an integer between 1
and 10 or 'No Limit'.
Solution 1:
Currently the integer values from 1 to 10 or No Limit are available to use
when entering a value in to Limit the report to a certain number of paths
per Timing constraint.
To edit this go from Implement-->Options-->Edit Template
(Implementation)--> Timing Tab. Then choose the Timing Report Format,
then the number of paths to report can be entered.
End of Record #2316
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |