Answers Database
M1.3/M1.4 CPLD: Fitter does not recognize the vcc labelled net as a special net name
Record #2341
Product Family: Software
Product Line: Merged Core
Problem Title:
M1.3/M1.4 CPLD: Fitter does not recognize the vcc labelled net as a
special net name
Problem Description:
Keywords: cpld, m1, fitter, vcc, net
Urgency: standard
General Description:
Xact-M1 no longer recognizes a sourceless net labelled vcc as
a special net name. This was allowed by the older versions,
but was not a design practice and is not a valid schematic
entry process.
Solution 1:
Solution:
Vcc nets should be connected to the "vcc" library element and
not left as sourceless nets labeled vcc.