Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


M1.3/M1.4 CPLD: Fitter does not recognize the vcc labelled net as a special net name


Record #2341

Product Family:  Software

Product Line:  Merged Core

Problem Title:
M1.3/M1.4 CPLD: Fitter does not recognize the vcc labelled net as a
special net name



Problem Description:
Keywords: cpld, m1, fitter, vcc, net

Urgency:  standard

General Description:

Xact-M1 no longer recognizes a sourceless net labelled vcc as
a special net name.  This was allowed by the older versions,
but was not a design practice and is not a valid schematic
entry process.



Solution 1:

Solution:

Vcc nets should be connected to the "vcc" library element and
not left as sourceless nets labeled vcc.




End of Record #2341

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals!

© 1998 Xilinx, Inc. All rights reserved
Trademarks and Patents