Return to Support Page
 homesearchagentssupportask xilinxmap

Answers Database


Flow Engine M1.3: Multi-Pass Place & Route summary report not shown until completion


Record #2359

Product Family:  Software

Product Line:  M1 Graphical/General

Problem Title:
Flow Engine M1.3: Multi-Pass Place & Route summary report not shown
until completion



Problem Description:
Keywords: report, browser, par, summary, multi-pass

Urgency: Standard

General Description:
The Design Manager Report Browser  does not provide access to the
Multi-Pass Place and Route summary results file while the process
is still running.


Solution 1:

Examine the history window for results.




Solution 2:

The results files will be in the revision directory. It is named design_name.par
.  You can use an editor to examine it.

Example path:

   xproj/ver1/p1_rev_21/design_name.par



End of Record #2359