Answers Database
M1.3 MAP: User-defined TIMESPEC constraints added outside the "SCHEMATIC" section of the .PCF file are commented out by MAP
Record #2397
Product Family: Software
Product Line: Merged Core
Problem Title:
M1.3 MAP: User-defined TIMESPEC constraints added outside the
"SCHEMATIC" section of the .PCF file are commented out by MAP
Problem Description:
Keywords: map timespecs pcf comment
Urgency: standard
General Description:
Reference Number: 13429
TIMESPEC constraints which are added by the user outside of
the:
<INPUT>
SCHEMATIC START;
.
.
.
SCHEMATIC END;
section of the .PCF file get commented out by MAP and
ignored when the design is re-processed .
Solution 1:
Remove the comment symbols from the .PCF file manually
for the desired constraints before running PAR on the
design.
End of Record #2397