XC5200: 5206- Incorrect pinouts for any parts with daycode earlier than 9620


Record #2502

Product Family:  Hardware

Product Line:  5200

Problem Title:
XC5200: 5206- Incorrect pinouts for any parts with daycode earlier than
9620



Problem Description:
Keywords: 5206, pinout, 100, 101

Urgency: HOT


The pins 100 and 101 for the 5206HQ340 package were
interchanged after the daycode 9620. Using parts that have a
daycode earlier than 9620 with the pinouts in the databook will
cause a short on the board between Vcc and GND.


Solution 1:

Xilinx will replace the parts. Call the local sales reps.



End of Record #2502