Answers Database
Foundation: Can not load/open Foundation after renaming drive, susie.ini
Record #2537
Product Family: Software
Product Line: Aldec
Problem Title:
Foundation: Can not load/open Foundation after renaming drive, susie.ini
Problem Description:
Key Words: Aldec, Foundation, Active Cad, susie.ini
Urgency: Standard
General Description:
After renaming the drive which has the Foundation tools
installed on it, Foundation fails to start up and gives
an error about invalid paths in the susie.ini file.
Solution 1:
The susie.ini ascii file is located in the Windows directory
and contains variables pointing to the location of Foundation
tools. Edit the file and correct the variables so they
point to the new drive letter.
Solution 2:
The Susie.ini file may also be modified by selecting
File->Configuration from the Foundation Project Manager, and
then hitting the "View INI File" button.
End of Record #2537
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |