Foundation F1.3/F1.4, Logiblox: Do not change Logiblox symbol parameters on schematic


Record #2603

Product Family:  Software

Product Line:  Aldec

Problem Title:
Foundation F1.3/F1.4, Logiblox:	Do not change Logiblox symbol
parameters on schematic



Problem Description:
Keywords:  Logiblox, parameters

Urgency:  Standard

General Description:

Changes to Logiblox parameters via the Symbol Properties dialog
in the schematic editor will not be recognized.


Solution 1:

F1.3
====

To make changes to Logiblox symbol parameters, the Logiblox
component must be recreated through the Logiblox GUI (Tools ->
Logiblox... in the Project Manager) with the desired
parameters.  A separate Logiblox component (with a different
name)  must be created for each component with different
parameters.



Solution 2:

F1.4
====

In Foundation F1.4, the Logiblox GUI is available via the
Schematic Editor.  To change parameters of a Logiblox symbol,
simply double-click on the already-placed Logiblox symbol on
the schematic, and then hit "Configure Logiblox Symbol".  This
will bring up the Logiblox Module Selector dialog box.	Make
the desired changes, and recreate the logiblox component.

*Note:	if you wish to make changes to only this one instance
of the component (ie, you have other instances on the
schematic), then you should rename the new Module with a new
unique name.



End of Record #2603