Answers Database
M1.2 MAP: Problems with map3_nt.zip patch when installed in MYXILINX directory on Windows NT and Win95 systems: FATAL_ERROR:baspm:baspmdlm.c fail to ope n libx4kma.dll
Record #2641
Product Family: Software
Product Line: Merged Core
Problem Title:
M1.2 MAP: Problems with map3_nt.zip patch when installed in MYXILINX
directory on Windows NT and Win95 systems: FATAL_ERROR:baspm:baspmdlm.c fail to
ope
n libx4kma.dll
Problem Description:
Keywords: map, windows NT, 95, libx4kma.dll, 1.2.11, patch
Urgency: standard
General Description:
Map M1.2.11 with the map3_nt.zip patch may issue the
following error on Windows NT and Windows 95 platforms when
the following two conditions are true.
1. the patch is run from the Design Manager/Flow Engine GUI,
and
2. the patch is installed in a separate location pointed
to by the MYXILINX variable.
The following error is issued:
FATAL_ERROR:baspm:baspmdlm.c fail to open libx4kma.dll--1.2.11 map3_nt.zip patch
Depending on whether Map is run from the Design Manager
or from a DOS box in Windows NT, and whether the patch
is installed in a separate MYXILINX area or installed
over the Xilinx install directory, the results have been
observed to vary as follows:
WINDOWS NT:
===========
Patch installed Patch installed
to MYXILINX to XILINX dir.
--------------- ---------------
Run from GUI Can't load Works ok
------------ libx4kma.dll
Run from DOS
box system crash system crash
------------
Win95:
======
Patch installed Patch installed
to MYXILINX to XILINX dir.
--------------- ---------------
Run from GUI Can't load Works ok
------------ libx4kma.dll
Run from DOS
box Works ok Works ok
------------
In one test case, the design processes with no problem in
M1.3.7.
Solution 1:
In general, installing patches in a separate MYXILINX
directory on Windows NT systems shows varying degrees of
success from system to system.
The most reliable approach is to install any Xilinx patches
to the Windows95/NT platform software to the XILINX directory
instead. This means that any existing files are also in the
patch must be overwritten.
Reference Number: 18625
End of Record #2641