M1.3.7 Ngdbuild - Patch available for problem with Synopsys interface.


Record #2690

Problem Title:
M1.3.7 Ngdbuild - Patch available for problem with Synopsys interface.


Problem Description:
There is a problem with Synopsys designs that instatiate
one of the input latches that also has a TBUF driving the
PAD on the latch D pin.

Ngdbuild will incorrectly fail with the error:
ERROR basnu - logical net "DATA" has both active
and tristate drivers.

Reference # 18574


Solution 1:

There is a patch for M1.3.7 on the ftp site at:

ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/xsi_sol102897.tar.ZInternet Link
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/xsi_sun102897.tar.ZInternet Link
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/xsi_hp102897.tar.ZInternet Link
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/xsi-lib.zipInternet Link

This patch is also available from the M1.3 Performance Pack CD.



End of Record #2690