M1.3.7 Ngdbuild - Patch available for problem with Synopsys interface.
Record #2690
Problem Title:
M1.3.7 Ngdbuild - Patch available for problem with Synopsys interface.
Problem Description:
There is a problem with Synopsys designs that instatiate
one of the input latches that also has a TBUF driving the
PAD on the latch D pin.
Ngdbuild will incorrectly fail with the error:
ERROR basnu - logical net "DATA" has both active
and tristate drivers.
Reference # 18574
Solution 1:
There is a patch for M1.3.7 on the ftp site at:
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/xsi_sol102897.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/xsi_sun102897.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/xsi_hp102897.tar.Z
ftp://ftp.xilinx.com/pub/swhelp/M1.3_alliance/xsi-lib.zip
This patch is also available from the M1.3 Performance Pack CD.
End of Record #2690