Answers Database
Error: unable to open symbol template file. Logiblox: /sim/datareg0.1
Record #2692
Problem Title:
Error: unable to open symbol template file. Logiblox: /sim/datareg0.1
Problem Description:
Keywords: logiblox, symbol, template
Urgency: HOT
Error: Unable to open symbol template file: logiblox/sym/counter0.1
for reading.
Error: logiblox:/sym/counter0.1 is corrupt or incomplete.
Solution 1:
Add logiblox and simprim library in viewdraw.ini file.
Example of viewdraw.ini file:
dir [p] H:\customer
dir [w] H:\customer (primary)
dir [rm] F:\Xilinx\viewlog\data\xc4000e (xc4000e)
dir [r] F:\Xilinx\viewlog\data\logiblox (logiblox)
dir [rm] F:\Xilinx\viewlog\data\simprims (simprims)
dir [rm] F:\Xilinx\viewlog\data\builtin (builtin)
dir [rm] F:\Xilinx\viewlog\data\xbuiltin (xbuiltin)
Solution 2:
This error can possibly occur if the logiblox sym directory was
corrupted.
Solution is to copy them back from the CD over to where logiblox
was installed.
End of Record #2692
For the latest news, design tips, and patch information on the Xilinx design environment, check out the Xilinx Expert Journals! |